Specification :                                                                    
-    Device category (Class)                                               :    Class 1            
-    Noise measuring range                                                :    25 ÷ 140dB            
-    Noise measurement resolution                                     :    0.1 ÷ 0.01dB            
-    Frequency range                                                         :    10kHz ÷ 20kHz            
-    Dynamic range                                                            :    90dB            
-    Measurement of sound pressure level (SPL)                                                                
-    Measurement of equivalent noise levels (Leq)                                                                
-    Frequency weighting                                                    :    A/C/Z A/            
-    Integration over time                                                     :    Fast/Slow/Impulse            
-    Statistical                                                                   :    LAFp, LAFmax, LAF5, LAF10, LAF50,             
                                                                                       :    LAF90, LAF95, LAFmin, SD, LAeq1s, LAeq,T, LAE, LAfeqT.            
-    Level linear range                                                         :    >90dB            
-    Resolution                                                                   :    0.1dB (Statistic), 0.01dB (1/1 e 1/3 OCT)             
-    Frequency range                                                          :    10Hz ÷ 20kHz (±0.2dB) ; 1Hz ÷ 23kHz (±1.0dB)             
-    Range gain                                                                  :    -10dB, 0dB, 10dB, 20dB, 30dB, 40dB             
-    Range control error                                                       :    ? 0.1dB             
-    Self-generated noise voltage:                                         :    <4> -    Background noise                                                        :    <13dB> -    Total noise                                                                   :    <18dB> -    Measuring voltage range                                               :    15?V ÷10V (TRMS)             
-    Frequency weighting                                                    :    A / C / Z            
-    Time weighting                                                            :    Fast, Slow, Impulse, Peak C+, Peak C-            
-    A/D internal converter                                                  :    24 bit             
-    ampling rate                                                                :    20.8?s (48kHz)             
-    ntergration time                                                           :    1s ÷ 24h pre-defined or customized            
-    Internal memory                                                          :    64kBytes flash memory            
-    Data storage                                                               :    max 128 groups / max 256 calibrations             
-    Peak measurements (Peak-, Peak+)                                                                
-    Display of MAX/MIN values of SPL                                                                
-    Statistic analysis of noise with "A" weighting                                                                
-    SPL analysis in 24H                                                                
-    Spectrum analysis with octave-band filter (1/1)                :    19Hz ÷ 16kHz            
-    Spectrum analysis with 1/3 octave-band filter                                                                
-    Provided mobile calibrator                                              :    Class 1            
-    Manual calibration with trimmer                                                                
-    Precise calibration with internal procedure                                                                
-    Pre-polarized “1/2” condenser microphone                                                                
-    AC and DC analogue outputs with 3.5mm jack                 :    Only AC            
-    Internal memory for data saving                                       :    128            
-    Recalling of results on the display                                                                
-    Mini-USB interface for PC connection                                                                
-    Windows software for saved data analysis                                                                
-    Display                                                                          :    LCD 240 x 160            
-    Display backlight                                                                
-    Power supply                                                                
-    Provided external power supply                                                                
-    Reference standards                                                       :    IEC61672 Class 2 - IEC61620 Class 2            
-    Size (LxWxH) (mm)                                                        :    285 x 90 x 39            
-    Weight in grams (batteries included)                                :    500            
-    Guidelines                                                                
                                                                    
-    CE MARK                                                                
-    DLgs. 81/08                                                                
-    EMC 2014/30/EU                                                                
-    EMC: IEC/EN61326                                                                
-    IEC60651 Class 1                                                                
-    IEC60804 Class 1                                                                
-    IEC61260 Class 1                                                                
-    IEC61672 Class 1                                                                
-    IEC/EN61010-1